Экономичные и высокопроизводительные логические контроллеры Fatek серии FBs предназначены для использования в средствах автоматизации для измерения, контроля и управления технологическими процессами как в автономном режиме, так и в составе распределенных систем. Благодаря технологии System On Chip (SoC), они дешевле и эффективнее своих аналогов.
FBs-2DA 2 Channels Analog Output Module Specifications Total Channels –2 Channels Resolution- bit Signal Resolution - 0.3mV(Voltage), 0.61uA(Current) I/O Points Occupied – RO(Output Register) Conversion Time- Updated each scan Accuracy- % Max. and Min. output loadingVoltage Output- ~1M Current Output- 0~ Introduction FBs-2DA is one of the analog output modules of FATEK FBs series PLC. It provides channels of bit D/A output. Base on the different jumper settings it can provide varieties of current or voltage output signal. The output code can be configured as unipolar or bipolar which makes the relation of output code and real output signal more intuitive. For safety, the output signal will be automatically forced to zero(0V or 0mA) when the module is not serviced by CPU for 0.5 second Output Range-10~+10V, -5~+5V, 0~10V, 0~5V -20~+20mA, -10~+10mA, 0~20mA, 0~10mA Isolation- Transformer(Power) and photo-coupler(Signal) Indicator(s) - 5V PWR LED External Power and Consu...
FBs-6AD 6 Channel A/D Input Module Specifications Total Channels - CH Resolution- or bit Signal Resolution - 0.3mV(Voltage), 0.61uA(Current) I/O Points Occupied - RI(Input Register) Conversion Time- Updated each scan Accuracy- % Max. Absolute Input Rating15V(Voltage), mA(Current) Software Filter- Moving average Average Samples- 1~ configurable Introduction FBs-6AD is one of the analog input modules of FATEK FBs series PLC. It provides channels A/D input with or bit effective resolution Base on the different jumper settings it can measure the varieties of current or voltage signal. The reading value is represented by a bit value no matter the effective resolution is set to or bit. In order to filter out the field noise imposed on the signal, it also provides the average of sample input function. Input Impedance- .2K(Voltage), (Current) Measurement Range-10~+10V, -5~+5V, 0~10V, 0~5V -20~+20mA, -10~+10mA, 0~20mA, 0~10mA Isolation- Transformer(Power) and photo-coupler(Sig...
FBs-7SG1 LED Display Control Module Specification Display Mode- Decode and Non-Decode Display Duty Cycle- 1/8 Update Rate- mS Control Capability8 digits of seven-segment LED display(include decimal point) or digits of segment alphanumerical LED display or independent LED displays I/O Points Occupied– Decode- output register (OR) Non-Decode- output register (OR) Introduction FBs-7SG1 is one of the LED display control modules of FBs-PLC series. One 7SG1 module can support up to digits of seven-segment LED display (include decimal point) or digits of -segment alphanumerical LED display or independent LED displays. The driving voltage of this module is selectable from 2.4V~11.7V in order to meet the requirement of driving different size of LED display. The display pattern can be controlled directly by setting the content of output register. For the application involved the leading zero effect or segment alphanumerical display, can use the TDSP function instruction for ...
FBs-7SG2 LED Display Control Module Specification Display Mode- Decoded and Non-Decoded Display Duty Cycle- 1/8 Update Rate- mS Control Capability digits of seven-segment LED display(include decimal point) or digits of segment alphanumerical LED display or independent LED displays I/O Points Occupied– Decode- output register (OR) Non-Decode- output register (OR) Signal Connector- Pin IDC connector Introduction FBs-7SG2 is one of the LED display control modules of FBs-PLC series. One 7SG2 module can support up to digits of seven-segment LED display (include decimal point) or digits of -segment alphanumerical LED display or independent LED displays. The driving voltage of this module is selectable from 2.4V~11.7V in order to meet the requirement of driving different size of LED display. The display pattern can be controlled directly by setting the content of output register. For the application involved the leading zero effect or segment alphanumerical display, ca...
FBs-B2A1D Analog I/O Combo Expansion Board Specification Analog Input Total Channels : Channels Resolution : bits Coding Format : bits ( ) Signal Resolution : 2.44mV(Voltage), 4.88uA(Current) Registers Occupied : Registers ( D D ) Conversion Time : Updated each scan Accuracy : % Max. Absolute Input Rating : V(Voltage), mA(Current) Input Impedance : K(Voltage), (Current) Introduction FBs-B2A1D is one of the analog I/O boards of FATEK FBs series PLC. For analog output it provides channel of -bit (coded in bits) output signal. For safety, the output signal will be automatically forced to zero(0V or 0mA) when the module is not serviced by CPU for 0.5 second. For analog input it provides channels of A/D inputs with -bit (coded in bits) resolution. The Input/Output signal types (voltage or current) can be selected by the field wiring. Measurement Range : V(Voltage) mA(Current) Analog Output Total Channels : Channel Resolution : bits Coding Format : bits ( ) Signal ...
FBs-B2A1D Analog I/O Combo Expansion Board Specification Analog Input Total Channels : Channels Resolution : bits Coding Format : bits ( ) Signal Resolution : 2.44mV(Voltage), 4.88uA(Current) Registers Occupied : Registers ( D D ) Conversion Time : Updated each scan Accuracy : % Max. Absolute Input Rating : V(Voltage), mA(Current) Input Impedance : K(Voltage), (Current) Introduction FBs-B2A1D is one of the analog I/O boards of FATEK FBs series PLC. For analog output it provides channel of -bit (coded in bits) output signal. For safety, the output signal will be automatically forced to zero(0V or 0mA) when the module is not serviced by CPU for 0.5 second. For analog input it provides channels of A/D inputs with -bit (coded in bits) resolution. The Input/Output signal types (voltage or current) can be selected by the field wiring. Measurement Range : V(Voltage) mA(Current) Analog Output Total Channels : Channel Resolution : bits Coding Format : bits ( ) Signal ...
FBs-B2DA Analog Output Expansion Board Specification Total Channels : Channels Resolution : bits Coding Format : bits ( ) Signal Resolution : 2.44mV(Voltage), 4.88uA(Current) Registers Occupied : Register ( D D ) Conversion Time : Updated each scan Accuracy : % Max. and Min. output loading : Voltage Output : 2K 1M Current Output : Output Range : V(Voltage) +20mA(Current) Internal Power Consumption : 5V, mA(Max. load) Operating Temperature : Storage Temperature : - Introduction FBs-B2DA is one of the analog output expansion boards of FATEK FBs series PLC. it provides channels of -bit (coded in bits) analog outputs. For safety, the output signals will be automatically forced to zero(0V or 0mA) when the board is not serviced by CPU for 0.5 second. The Output signal types (voltage or current) can be selected by the field wiring. Pin Assignment Analog Output VO0 IO0 VO1 IO1 Gnd 1/3 FBs- B2DA Wiring Diagram Analog Output Expansion Board Characteristics C...
FBs-B2DA Analog Output Expansion Board Specification Total Channels : Channels Resolution : bits Coding Format : bits ( ) Signal Resolution : 2.44mV(Voltage), 4.88uA(Current) Registers Occupied : Register ( D D ) Conversion Time : Updated each scan Accuracy : % Max. and Min. output loading : Voltage Output : 2K 1M Current Output : Output Range : V(Voltage) +20mA(Current) Internal Power Consumption : 5V, mA(Max. load) Operating Temperature : Storage Temperature : - Introduction FBs-B2DA is one of the analog output expansion boards of FATEK FBs series PLC. it provides channels of -bit (coded in bits) analog outputs. For safety, the output signals will be automatically forced to zero(0V or 0mA) when the board is not serviced by CPU for 0.5 second. The Output signal types (voltage or current) can be selected by the field wiring. Pin Assignment Analog Output VO0 IO0 VO1 IO1 Gnd 1/3 FBs- B2DA Wiring Diagram Analog Output Expansion Board Characteristics C...
FBs-2ARTD4 2 Channel A/D Input Module /4 Channel RTD Temperature Input Module Analog Input Specification Channels2CH Resolution or bits Signal Resolution 0.3mV(Voltage), 0.61uA(Current) I/O Points Occupied IR(Input Register) scan Accuracy1 % Max. Absolute Input Rating V,30mA Average Samples1~ configurable Input Impedance .2k(Voltage) (Current) Measurement Range-10~+10V, -5~+5V ,0~10V, 0~5V, -20~+20mA, -10~+10mA, 0~20mA, 0~10mA RTD Specification Channels4CH Resolution0.1 or I/O Points Occupied IR(Input Register) DO(Discrete Output) Conversion Time1 or Sec. Sensor TypePt ,Pt (DIN or JIS) Software FilterMoving average Average Samples1~ Measurement Range Pt : - ~ Pt : - ~ Conversion TimeUpdated each Accuracy1% Introduction FBs-2ARTD4 is one of the Analog and Temperature mixed input modules of FATEK FBs series PLC. For analog input it provides channels A/D input with or bit effective resolution. Base on the different jumper settings it can measure the varieties of c...
FBs-2ATC4 2 Channel A/D Input Module /4 Channel Thermo -Couple Temperature Input Module Analog Input Specification Channels2CH Resolution or bits Signal Resolution 0.3mV(Voltage), 0.61uA(Current) I/O Points Occupied IR(Input Register) scan Accuracy1 % Max. Absolute Input Rating V,30mA Average Samples1~ configurable Input Impedance .2k(Voltage) (Current) -5~+5V ,0~10V, 0~5V, -20~+20mA, -10~+10mA, 0~20mA, 0~10mA Thermo-Couple Specification Channels4CH Resolution0.1 or I/O Points Occupied IR(Input Register) DO(Discrete Output) Conversion Time2 or Sec. Sensor TypeJ,K,R,S,E,T,B ,N Software FilterMoving average Average Samples1~ CompensationBuilt in cold junction compensation Measurement Range J:- ~ ; K:- ~ R:0~ ; S:0~ B: ~ ; N:- ~ Conversion TimeUpdated each Accuracy(1%+1) Introduction FBs-2ATC4 is one of the Analog and Temperature mixed input modules of FATEK FBs series PLC. For analog input it provides channels A/D input with or bit effective resolution. Base on t...
FBs-4PT 4 Channels of Potential Meter Input Module Specifications Total Channels - CH Resolution- or bit I/O Points Occupied - RI(Input Register) and dummy RO(Register Output) Conversion Time- Updated each scan Accuracy- % Impedance of Applicable Potential Meter1 K~ K Input Range of Voltage Signal – ~ V Driving Voltage Output – V Software Filter- Moving average Average Samples- 1~ configurable Isolation- Transformer(Power) and photo-coupler(Signal) Indicator(s) - 5V PWR LED Supply Power- V-15%/+20%, 2VA Internal Power Consumption- 5V, mA Operating Temperature- ~ Storage Temperature- - ~ Dimensions- (W)x90(H)x80(D) mm Introduction FBs-4PT is one of the analog input modules of FATEK FBs series PLC. It provides channels potential meter input or unipolar single ended voltage input with or bit effective resolution. The reading value is represented by a bit value no matter the effective resolution is set to or bit. In order to filter out the field noise imposed on the signal, ...
FBs-B4AD Analog Input Expansion Board Specification Analog Input Total Channels : Channels Resolution : bits Coding Format : bits ( ) Signal Resolution : 2.44mV(Voltage), 4.88uA(Current) Registers Occupied : Registers ( D D ) Conversion Time : Updated each scan Accuracy : % Max. Absolute Input Rating : V(Voltage), mA(Current) Input Impedance : K(Voltage), (Current) Measurement Range : V(Voltage) Introduction FBs-B4AD is one of the analog Input expansion boards of FATEK FBs series PLC. For analog input it provides channels of A/D inputs with -bit (coded in bits) resolution. The Input signal types (voltage or current) can be selected by the field wiring. mA(Current) Indicator(s) : No Internal Power Consumption : 5V, mA (Max. Load) Operating Temperature : Storage Temperature : - Pin Assignment 1/3 FBs-B4AD Wiring Diagram FBs-B4AD Analog Input Expansion Board 75K VI K * V CH0 Voltage Input OR II K VI K I CH0 Current Input *<...
FBs-CM25C Isolated RS to RS /RS Signal Converter Specifications Maximum Speed - Kbps Flow Control- Automatic Interface SignalsRS - RX(3),TX(2),GND(5) RS - D+, D-,GND RS – TX+,TX-,RX+,RX- ConnectorsRS - DB9F Power,RS /RS - Pin Euro plug Isolation method- Transformer (Power) and optical (Signal) DIP switch setting RS Terminator- Introduction FBs-CM25C is a RS to RS /RS bi-directional signal converter of FBs-PLC series. This module is designed for stand alone operation and can work not only with the FBs-PLC but also other brands of controller. The feature of isolation between each ports, protect this module from damaging when the voltage difference between the sub systems is high. While installation, this module can be mounted on DIN-Rail or securely be fastened by screw. User can select the RS or RS working mode by setting the DIP switches at front panel. There is a built-in resistor in this module for RS network termination which can also set on or off via front pan...
Ethernet Interface Module Support multiple clients access Support server or client mode Support FATEKor Modbus-TCP protocol IP based access control .4 Kbps high speed baud rate for serial interface Network on line configuration Specifications Network Interface- BaseT Network Protocol- TCP/IP Application Protocol- FATEK, Modbus-TCP Operation Principle- Serial to Ethernet conversion PLC interface- Port4 RS interface Generic Port- Port3, RS interface PLC Communication Speed- .4 Kbps (Max.) Working Mode- Server or client Application IP Port numberModbus-TCP – FATEK – or defined by user Max. TCP Connection – sessions Introduction FBs-CM25E is an Ethernet interface module of FBs-PLC series. It enables the capability of FBs-PLC to access the other controllers or devices thru the Ethernet network actively(client) or passively(server). Besides the FBs MA model CPU, all MC, MN CPU can be remotely monitored and diagnosed thru Internet by using this mod...
Ethernet Interface Module Support multiple clients access Support server or client mode Support FATEKor Modbus-TCP protocol IP based access control .4 Kbps high speed baud rate for serial interface Network on line configuration Specifications Network Interface- BaseT Network Protocol- TCP/IP Application Protocol- FATEK, Modbus-TCP Operation Principle- Serial to Ethernet conversion PLC interface- Port4 RS interface Generic Port- Port3, RS interface PLC Communication Speed- .4 Kbps (Max.) Working Mode- Server or client Application IP Port numberModbus-TCP – FATEK – or defined by user Max. TCP Connection – sessions Introduction FBs-CM55E is an Ethernet interface module of FBs-PLC series. It enables the capability of FBs-PLC to access the other controllers or devices thru the Ethernet network actively(client) or passively(server). Besides the FBs MA model CPU, all MC, MN CPU can be remotely monitored and diagnosed thru Internet by using this mod...
FBs-CM5H Specifications 4 Port RS Hub Total Ports- Ports Maximum Speed- 1Mbps Flow Control- Automaic Interface SignalsRS interface- +, -,GND Connector- Terminal block Isolation Method- Transformer (Power) and optical (Signal) RS TerminatorBuilt in, each port can be set individually. Introduction FBs-CM5H is a RS repeater module of FBs-PLC series. This module is designed for stand along operation and can work not only with the FBs-PLC but also other brands of controller. The feature of isolation between each ports protect this module from damaging when the voltage difference between the sub systems is high. This module can concentrates the multiple RS bus segments into one unify RS network. The RS network can only suit for bus structure topology, when there is a need to deploy the star topology then using this module is a right answer. Indicators 5V PWR LED indicator Active status LED indicators Collision status LED indicators External Power - V-15%/+20%, 2W Power P...
FBs-CM5R Isolated RS Repeater Specifications Maximum Speed- 1Mbps Interface SignalsRS RTX+, RTX-, GND ConnectorsRS interface- Pin Euro plug Power- Pin Euro plug Isolation method- Transformer (Power) and optical (Signal) RS TerminatorBuilt in, each port can be set individually Introduction FBs-CM5R is a RS repeater module of FBs-PLC series. This module is designed for stand along operation and can work not only with the FBs-PLC but also other brands of controller. The feature of isolation between each ports protect this module from damaging when the voltage difference between the sub systems is high. While installation, the module can be mounted on DIN-Rail or securely be fastened by screw. No termination(OFF) With termination(ON) Indicators5V PWR LED indicator RS interface RX LED indicator External Power- V-15%/+20%, 0.5W Power Protection- Reverse polarity protection Operating Temperature- ~ Storage Temperature - - ~ Dimension- (W)x90(H)x73(D) mm Dim...
FBs-4DA/2DA 4 or Channels Analog Output Module Specifications Total Channels – 4(4DA) or 2(2DA) Channels Resolution- bit Signal Resolution - 0.3mV(Voltage), 0.61uA(Current) I/O Points Occupied – 4(4DA) or 2(2DA) RO(Output Register) Conversion Time- Updated each scan Accuracy- % Max. and Min. output loadingVoltage Output- ~1M Current Output- 0~ Introduction Output RangeFBs-4DA and FBs-2DA are two of the analog -10~+10V, -5~+5V, 0~10V, 0~5V output modules of FATEK FBs series PLC. -20~+20mA, -10~+10mA, 0~20mA, 0~10mA They provide and channels bit D/A Isolation- Transformer(Power) and photo-coupler(Signal) output respectively. Base on the different Indicator(s) - 5V PWR LED jumper settings it can provide varieties of current or voltage output signal. The output External Power and Consumptioncode can be configured as unipolar or bipolar V-15%/+20%, which makes the relation of output code and mA(4DA) or mA(2DA) max. real output signal more intuitive. For safety, the output si...
FBs-CMGSM User’s Manual 1. Introduction FBs-CMGSM is the communication module for FATEK PLC systems using GSM network to transfer the data. TC- JAVA OPEN CODE Cinterion (formerly Siemens) quad band GSM module / / / MHz and mAh Li-Ion battery are used. With the same HW, there are three different ways of operation available. The first one is monitoring and remote control of PLC via SMS. FBs-CMGSM reads periodically PLC registers containing a flag to send SMS, if the flag is set, FBs-CMGSM reads destination phone number and string of characters (text), sends SMS and clears the flag. If there is a SMS received by FBs-CMGSM, it is written into PLC registers including another flag “SMS received” to be processed by PLC program. At the end the PLC program clears this flag. So these operational SMS must be processed by PLC program both on SMS reception and SMS sending. Some status and event SMS are predefined in FBs-CMGSM (eg. “PLC power OFF”) and only the destination phone number have to...
FBs-RTD16 Channel RTD Temperature Input Module Specifications Total Channels - CH Resolution- 0.1 or I/O Points Occupied – RI(Input Register) Discrete Output(DO) Conversion Time- or Seconds Accuracy- % Sensor Type- Pt- , Pt (JIS or DIN) Software Filter- Moving average Average Samples- 1,2,4,8, configurable Introduction FBs-RTD is one of the temperature input modules of FATEK FBs series PLC. It provides channels of RTD temperature measurement input with 0.1 or resolution. The scan rate for 0.1 resolution is seconds, while the scan rate for resolution is seconds. This module provides three-wire connection for RTD temperature sensor, thus can automatically compensate the resistance introduced by the wiring. Measurement RangePt : - ~ Pt : - ~ Isolation- Transformer(Power) and photo-coupler(Signal) Indicator(s) – 5V PWR LED Supply Power- V-15%/+20%, 2VA Internal Power Consumption- 5V, mA Operating Temperature- ~ Storage Temperature- - ~ Dimensions- (W)x90(H)x80(D) mm D...
FBs-RTD6 6 Channel RTD Temperature Input Module Specifications Total Channels - CH Resolution- 0.1 or I/O Points Occupied – RI(Input Register) Discrete Output(DO) Conversion Time- or Seconds Accuracy- % Sensor Type- Pt- , Pt (JIS or DIN) Software Filter- Moving average Average Samples- 1,2,4,8, configurable Introduction FBs-RTD6 is one of the temperature input modules of FATEK FBs series PLC. It provides channels of RTD temperature measurement input with 0.1 or resolution. The scan rate for 0.1 resolution is seconds, while the scan rate for resolution is second. This module provides three-wire connection for RTD temperature sensor, thus can automatically compensate the resistance introduced by the wiring. All the optional features of this module are software configurable, there are no hardware jumpers or switches for user to setup. Measurement RangePt : - ~ Pt : - ~ Isolation- Transformer(Power) and photo-coupler(Signal) Indicator(s) – 5V PWR LED Supply Power- V-15%/+...
FBs-TC16 Channel Thermo-Couple Temperature Input Module Specifications Total Channels - CH Resolution- 0.1 or I/O Points Occupied – RI(Input Register) Discrete Output(DO) Conversion Time- or Seconds Accuracy- (1 %+1) Sensor Type- J,K,R,S,E,T,B,N Software Filter- Moving average Average Samples- 1,2,4,8, configurable Introduction FBs-TC is one of the temperature input modules of FATEK FBs series PLC. It provides channels of thermo-couple temperature measurement input with 0.1 or resolution. The scan rate for 0.1 resolution is seconds, while the scan rate for resolution is seconds. The cold junction compensation is carried out inside the module, also it provides wire broken detection feature. To give the user more choices for the selection of thermo-couple type and in order to enhance the noise immunity, the isolation scheme is per channel basis. All the optional features of this module are software configurable, there are no hardware jumpers or switches for user to setup....
FBs-TC2 2 Channel Thermo-Couple Temperature Input Module Specifications Total Channels - CH Resolution- 0.1 or I/O Points Occupied – RI(Input Register) Discrete Output(DO) Conversion Time- or Seconds Accuracy- (1 %+1) Sensor Type- J,K,R,S,E,T,B,N Software Filter- Moving average Average Samples- 1,2,4,8, configurable Introduction FBs-TC2 is one of the temperature input modules of FATEK FBs series PLC. It provides channels of thermo-couple temperature measurement input with 0.1 or resolution. The scan rate for 0.1 resolution is seconds, while the scan rate for resolution is seconds. The cold junction compensation is carried out inside the module, also it provides wire broken detection feature. To give the user more choices for the selection of thermo-couple type and in order to enhance the noise immunity, the isolation scheme is per channel basis. All the optional features of this module are software configurable, there are no hardware jumpers or switches for user to setup...
FBs-TC6 6 Channel Thermo-Couple Temperature Input Module Specifications Total Channels - CH Resolution- 0.1 or I/O Points Occupied – RI(Input Register) Discrete Output(DO) Conversion Time- or Seconds Accuracy- (1 %+1) Sensor Type- J,K,R,S,E,T,B,N Software Filter- Moving average Average Samples- 1,2,4,8, configurable Introduction FBs-TC6 is one of the temperature input modules of FATEK FBs series PLC. It provides channels of thermo-couple temperature measurement input with 0.1 or resolution. The scan rate for 0.1 resolution is seconds, while the scan rate for resolution is seconds. The cold junction compensation is carried out inside the module, also it provides wire broken detection feature. To give the user more choices for the selection of thermo-couple type and in order to enhance the noise immunity, the isolation scheme is per channel basis. All the optional features of this module are software configurable, there are no hardware jumpers or switches for user to setup...