FATEK Automation Corporation Operation Manual for Ladder Program Simulation of Winproladder V1. /6/30 Contents Operation manual for ladder program simulation . FEATURES . LIMITATION OF PROGRAM SIMULATION . OPERATION OF PROGRAM SIMULATION .1 Open ladder program 2 Enter simulation mode 3 Start execution of program simulation .4 Pause of program simulation 5 Proceed to program simulation 6 Control scanning .6.1 Single scan .6.2 Multiple scan .6.3 Continuous scan 7 Set address breakpoint of program execution 8 View Address Breakpoint List 9 Setup Data Breakpoint . Stop Simulation . End Simulation . COMMUNICATE WITH SIMULATED PROGRAM 1 Communication function setup .1.1 Serial port communication setup 1.2 Internet communication setup Page 2 Operation manual for ladder program simulation 1. Features Can simulate the FATEK PLC ladder program execution without PLC connection. With providing single/multiple/continuous scan mode, the execution result at each scan end ca...
Introduction This tutorial explains how to build an application by using the Winproladder programming package to write a ladder control program. In this tutorial we will not tackle the advanced features of WinProladder, only the basic operations needed to build a simple application will involved. Hope this will lead the user into the world of WinProladder with less efforts. Description of sample program The application we will build in this tutorial is described as below: Write a control program to generate a moving LED pattern by using the output indicators. The time chart of output is shown below At first Y0 will be 'on' for one second. After that Y1 will also 'on'. This will cycle to Y2 then Y . After Y7 is 'on', the next time all output will all be 'off' for second. This procedures will repeat again as described above. The corresponding control ladder program is shown at below: The content of element comment will be built is shown below General Features · Win...
Исправленные файлы для версии 2.34 rel.7228 исправлена ошибка с отображением русских текстов в программе распакуйте содержимое архива в каталог где установлен ProLadder обычно это 'C:\Program Files\Fatek\WinProladder\'
> New Addition Function Instruction : 1. F .I -> F(Conversion of integer to floating number) 2. F .F -> I (Conversion of floating point number to integer) 3. F .FADD(Floating point number addition) 4. F .FSUB(Floating point number subtraction) 5. F .FMUL(Floating point number multiplication) 6. F .FDIV(Floating point number division) 7. F .FCMP(Floating point number compare) 8. F .FZCP(Floating point number zone compare) 9. F .FSQR(Floating point number square root) .F .FSIN(SIN trigonometric instruction) . F .FCOS(COS trigonometric instruction) . F .FTAN(TAN trigonometric instruction) . F .FNEG(Change sign of the floating point number) . F .FABS(Floating point number absolute value) Floating point number can be entered and displayed in status page : ROR Registers can display both Decimal and Hexdecimal : Correcting the bug which ladder program can be saved to PLC by Modem : ...
WinProladderV2.31-Build: Change Note 1. Modify counter instruction input character : CLK PLS 2. Modify display windows of I/O Configuration : CLK K/R Up Dn MK PLS P/R UP DN MSK 3. Correcting the bug which can’t use pointer(VZ). 4. Correcting the bug which Fun can’t use derivative instructions(D P). ...
WinProladder V2. Change note : 1. Add the check Item “ The data to be not read back when power up after initialization” which in MEMORY PACK operations window : 2. Add the warning page when user want to execute “run editing” mode : 3. Debug bellows : a. When PLC(FBe-Series) in on-line mode, if entered value into DRXXXX in status page then PLC(FBe-Series) will require stop. b. When execute System Backup item, if selecting both Timer/Counter Register and File Register then File Register will be cleared. c. Restricting entered RXXXV, RXXXZ, RPxPx, and DPxPx in status page. d. If the length of table over words in project while saved project into PLC will occur communication format not correct. e. Modifying Time Out setting. f. When PLC in on-line mode, if changed port0’s baud rate then PLC will show “ Connection Fail! want to connect again?” message. e. If execute “RUN” command and off line immediately, sometimes can’t end processing instantly. ...
WinProladderV2. change note : 1. Add PLC connection Auto Check function 2. Add B2A1DB2DA module information 3. if ladder has been setting password, it will request password when executing MEMORY PACK System Backup. 4. ModBus communication table can enter 1xxxxx3xxxxx code(slave). 5. Add on line HELP function(only function instruction). 6. FBs MA main unit can support FUN (High speed PWM). Debug items : Correct bug below. 1. MEMORY PACK operation error(always execute System Backup). 2. The fonts of ModBus communication table too small. 3. Network copy can arrive Words( Words before). 4. When modify the average of temperature must stop. ...
WinProladderV2. ChangeNote Add “Froce Run Input” setting item : FUN add parameter - - - - - and setting item: FUN add DRVZMD0MD0 and MD0 setting item: Increasing Ladder memory size from word Version 2.33 word Version 2.34 Modifying MEMORY PACK configuration windows : Version 2.33 Version 2.34 Debug : 1. When one network(NXXX) arrive rows, if execute insert function(Shift + Insert) then system edit will incorrectly. 2. Can’t key in ”2D ” in ASCII Table. 3. When unidentified code in ROR area, connection must be rebuilt. 4. In on-line status, the delay time of Port3 and Port4 can’t be configured correctly. ...
WinProladder V2. ChangeNote 1. Add FUN .MHSPO(Multi-Axis high speed pulse output) 2. Add Multi Axis positioning table 3. Add ”UNDO” Function 4. Add Special Registers & Special Coils help (F2) 5. Add “Horizontal long” operation 6. Add “MEMORY PACK operations” in Quick Control 7. Add “FBs-B4AD” Module 8. “Auto-shift” while Function space not enough. 9. Modifying “I/O Numbering” state 10. Add register information in FUN table ...
WinProladderV2. Change Note New features 1. Import I/O numbering from PLC 2. Check the existence of the PLC with the same station number that current edited PLC intent to change. Modifications 1. ROM PACK operation screen Original V2.35 New V2.36 ROM PACK operation screen will be displayed If the PLC OS is below V4.46 Or If the PLC OS is V4. or after 2. Issue a warming message while quit from editing without writing updated program into ROM pack. 3. Issue a warming message while save the new program to PLC with the different station number embedded in the program. 4. Change the default printing margin to 8. Bugs Fixed 1. Fix the bug that when disconnect then reconnect the PLC connection, the communication will encounter error situation very often. 2. Fix the bug that when perform the automatic PLC connection and the result is fail, the content of the communication script will be shown incorrectly. 3. Fix the bug that It will raise an unexpected error m...
WinProladderV2. Function change explanation Increases Function instruction F34.MLC (Multiple Linear Conversion) Additional function: Below increases the function 1.Increases FBs-1LC and FBs-VOM module’s setting. 2.Addition [Check power supply capacity] function key. Revision function: Below revises the function 1.The revision works as [Connect to PLC], and non-open the associated project file, execute table instruction’s inspection and reconstructing table’s content. 2.The revision works as before enters [ROR Register], inspection from the ROR were used by table function, and move the table’s content to ROR. 3.The revision works as after confirmation from table edition, the tree-view on left side maintains the previous position. 4.The revision works as under [Element Comment] or [Element Statistics], records the previous cursor position. 5.The revision works as under [Off-Line], display the item’s value of [Status Page]. 6.The revision works as writing code to ROM PACK need input th...
WinProladder V2. update explanation Add “FUN” instruction New function 1.Can set to connect Ethernet by inputting domain-name Function revision function 1.The revision works as [Connect to PLC], and non-open the associated project file, execute F table instruction’s inspection and reconstructing table’s content. 2.Updata function of customer ID code inspection Correction 1.The software high speed counter of FBs-MA models can input X4-X .The new English version will be able to show message of NTC6 and B2A1D/B2DA/B4AD 3.After V-Short contacts I/P/N won’t cause compile error 4.The communication buffer length will match limitation so won’t lead to communication fail ...
WinProladder V2. function update New “FUN” instruction F .= F .> F .< F . F .>= F .=< (equal) (bigger than .) (smaller than .) (not equal) (equal or bigger than .) (equal or smaller than .) F98.RAMP2 (DA soft up/down instruction) F .MPG (thumb-switch-wheel instruction) New function New Element Comment can set in PLC ladder or project. Function revision None Correction 1.”Element Comment with data leads to incorrect edition” was revised. 2.”Under [RunEdit], operate [Undo] will delete LBL” was revised. 3.”Execute [Compress to Column] then contact’s number become X0” was revised. ...
WinProladder V2. function updation New “FUN” instruction None New function None Function revision 1.FBs-MA modules are capable to operate group of Hardware High Speed Counter + group of High Speed Pulse Output + point Hardware Input Interruption. 2.PLC’s ROR’s single register writing change to continuously writing, so can shorten communication time. Correction 1.WinProladder in Server is now executable. ...
WinProladder V2. function updation New “FUN” instruction None New function 1.Addition the port number’s detection of Connect auto check. Function revision 1.The origin line at right side of coil to show. 2.The parameter of F92&F could input HSC2&HSC3. Correction 1. Revise mistake of “can’t print attached drawing & replace F ~F ’s parameter” 2. Revise mistake of “different syntax’s processing of step instruction by on-line & off-line treatment will lead to next unidentical connection” 3. Revise mistake of “when networks at line & columns, FUN edition will recognize one more row” 4. Revise mistake of “can’t print [Cross Reference]” ...
WinProladder V3. function updation New “FUN” instruction None New function 1.Addition [PLC]-[ Simulation ] 2.Addition command direct link Ethernet module (FBs-CBEH) 3.Addition optional models of B1/B1z series Function revision 1The FBs-MA models can be set HSC2 & HSC3(X8~X15) 2.The FBs-MA models can be key in F . HSPWM & F . MPG instructions 3.Records the screen location of [Toolbar ]-[ File]/[ View ]/[ Project ]/[ Ladder] Correction 1. Revise mistake of “Cannot [Save as] to file after FBe program with password conversion to FBs program” 2. Revise mistake of “B1/B1z program with element comments, will to be happened [Project data not consistent with PLC] on [On-Line] again“ 3. Revise mistake of “Does not save program to flash on [On-Line] of B1z when didn’t execute [Off-Line ] to close the winproladder in [On-Line] directly ...
WinProladder V3. function updation New “FUN” instruction None New functions 1.Add FBs-2LC model option 2.Add B1z-32M/B1-32M/B1-40XY/B1-L2A2D/B1-L4NTC models option Function revision 1. 2. B1/B1z models can set HSC2 & HSC3(X8~X15) B1 models can key in (OS:5.60) F31.CRC16/F32.ADCNV/ F59.->7SG/ F60.->ASC/F61.->SEC/F62.->HMS/ F80.MUXI/F81.PLSO/F84.TDSP/ F86.TPCTL/ F94.ASCWR/ F .MHSPO/F .MPG/ F .RW-FR/F .WR-MP/F .RD-MP/ F .I->F/F .F->I/F .FADD/F .FSUB/F .FMUL/ F .FDIV/F .FCMP/F .FZCMP/F .SQR/F .FSIN/ F .FCOS/ F .FTAN/F .FNEG/F .FABS/F .FLN/ F .FEXP/F .FLOG/F .FPOW/F .FASIN/F .FACOS/ F .FATAN 2. B1z models can key in (OS:5.10) F23.DIV48/ F30.PID/F31.CRC16/F32.ADCNV/F33.LCNV/F34.MLC/ F55.B->G/F59.->7SG/ F60.->ASC/F61.->SEC/F62.->HMS/ F80.MUXI/F81.PLSO/F82.PWM/F83.SPD/F86.TPCTL/ F95.RAMP/F98.RAMP2/ F .T->T/F .BT M/F .T SWO/F .T T C/F .T SHF/F .T ROT/ F .MAND/F .MOR/F .MXOR/F .MXNR/F .MINV/ F .MCMP/F .MBRD/F .MBWR/F .MBSHF/F .MBROT/ F .HSPWM/ F .MPG/ F .WR-MP/F .RD-MP/ ...
Update list of WinProladder V3.24 New “FUN” instruction None New functions 1.Add F .TXTDF:LADCOPY:CLOSE’s application Function revision None Correction 1.Revise mistake of “When B1z ROR size isn’t zero, then save to PLC, will lead to Ladder Checksum Error”. 2.Revise mistake of “B1 cannot enter C96~C , C ~C ,T ~T ” 3.Revise mistake of “After setting 1LC & 2LC’s status of I/O Configuration, cannot save to file ” ...
Update list of WinProladder V3.28 New “FUN” instruction 1. F .BLOCKEDITC:NAME and .BLOCKDSP:OPEN New functions 1. New model: FBs-2LCHR 2.[Project]-[Project Setup]-[Data Password] 3.[General Purpose Link Table]-[Receive even with error] Function revision Correction ...